{"id":3350,"date":"2023-04-13T14:50:00","date_gmt":"2023-04-13T06:50:00","guid":{"rendered":"http:\/\/www.controlsp.com\/index.php\/2023\/04\/13\/heat-pump-solutions-2\/"},"modified":"2023-04-13T18:19:53","modified_gmt":"2023-04-13T10:19:53","slug":"debugging-aids","status":"publish","type":"post","link":"https:\/\/www.controlsp.com\/index.php\/2023\/04\/13\/debugging-aids\/","title":{"rendered":"Debugging aids"},"content":{"rendered":"<h1 style=\"text-align: center;\"><strong>Debugging aids<\/strong><\/h1>\n<p><strong>Scenario 1<\/strong>: Using a computer to send control commands to the motor, monitor the motor operation status, debug the optimal motor operation status parameters, and update the motor control program in the driver.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-2915\" src=\"http:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/01-1-300x83.png\" alt=\"\" width=\"800\" height=\"220\" srcset=\"https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/01-1-300x83.png 300w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/01-1-768x212.png 768w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/01-1-600x165.png 600w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/01-1.png 940w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>1. Optimize motor operation status parameter modification<br \/>\nThe driver is connected to the PC software of the computer through a professional device (USB to 485). After a successful handshake, real-time reading, modification, and saving of the motor control parameters in the driver can be achieved. Motor debugging can be easily achieved without repeatedly brushing and writing the driver program.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-2916\" src=\"http:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/02-1-300x195.png\" alt=\"\" width=\"800\" height=\"520\" srcset=\"https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/02-1-300x195.png 300w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/02-1-768x499.png 768w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/02-1-600x390.png 600w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/02-1.png 933w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>2.Send control commands and monitor motor operation status<br \/>\nThe driver is connected to the PC software of the computer through a professional device (USB to 485). After a successful handshake, the driver can send a motor start\/stop command or rotational speed command. You can choose to monitor the data channel, monitor the operating current and other states of the motor, and monitor the temperature rise of the driver.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-2917\" src=\"http:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/03-1-300x194.png\" alt=\"\" width=\"800\" height=\"518\" srcset=\"https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/03-1-300x194.png 300w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/03-1-768x498.png 768w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/03-1-600x389.png 600w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/03-1.png 920w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>3.Fault recording function<br \/>\nThe driver is connected to the PC software of the computer through a professional device (USB to 485). After a successful handshake, the driver can read the historical fault record of the driver, as well as the fault code, rotational speed, temperature, current, voltage, and other information at the node where the fault occurred.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-2918\" src=\"http:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/111-300x203.png\" alt=\"\" width=\"800\" height=\"542\" srcset=\"https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/111-300x203.png 300w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/111-768x520.png 768w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/111-600x406.png 600w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/111.png 904w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>4.Update of motor control program in the driver<br \/>\nThe driver is connected to the PC software of the computer through a professional device (USB to 485). After a successful handshake, the motor control program in the driver can be updated for remote debugging.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-2919\" src=\"http:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/222-300x220.png\" alt=\"\" width=\"800\" height=\"587\" srcset=\"https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/222-300x220.png 300w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/222-768x563.png 768w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/222-600x440.png 600w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/222.png 878w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p><strong>Scenario 2<\/strong>: Using an Android phone to send control commands to the motor, monitor the motor operation status, and update the motor control program in the driver.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-2920\" src=\"http:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/01-2-300x106.png\" alt=\"\" width=\"800\" height=\"283\" srcset=\"https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/01-2-300x106.png 300w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/01-2-768x272.png 768w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/01-2-600x212.png 600w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/01-2.png 958w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>The driver is connected to the Android phone app through a dedicated Bluetooth device (developed by Zhouju). After a successful handshake, it can send a motor control rotation speed or start\/stop command to monitor the rotation speed, current, drive temperature, and other states of the motor. It can also update the motor control program in the driver through the app, which is simple and convenient to operate.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-2921\" src=\"http:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/02-2-300x205.png\" alt=\"\" width=\"800\" height=\"548\" srcset=\"https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/02-2-300x205.png 300w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/02-2-768x526.png 768w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/02-2-600x411.png 600w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/02-2.png 1019w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p><strong>Scenario 3<\/strong>: Use a computer to monitor the running status of the motor in real time, solve problems during motor debugging, and facilitate the discovery and resolution of problems.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-2922\" src=\"http:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/03-2-300x91.png\" alt=\"\" width=\"800\" height=\"242\" srcset=\"https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/03-2-300x91.png 300w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/03-2-768x232.png 768w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/03-2-600x181.png 600w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/03-2.png 972w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>The driver is connected to a computer PC software through a dedicated communication device (developed by Zhouju). After a successful handshake, it can monitor the rotational speed, current, algorithm parameters, sensor temperature, and other states of the motor in real time. The advantage of this method is that not only can remote debugging be achieved, but also control parameters can be adjusted based on real-time feedback status, enabling the load and drive to achieve the best matching working state.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-2923\" src=\"http:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/04-1-300x175.png\" alt=\"\" width=\"800\" height=\"466\" srcset=\"https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/04-1-300x175.png 300w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/04-1-768x448.png 768w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/04-1-600x350.png 600w, https:\/\/www.controlsp.com\/wp-content\/uploads\/2023\/03\/04-1.png 997w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Debugging aids Scenario 1: Using a computer to send control commands to the motor, monitor the motor operation status, debug the optimal motor operation status parameters, and update the motor control program in the driver. 1. Optimize motor operation status parameter modification The driver is connected to the PC software of the computer through a [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2915,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[57],"tags":[],"class_list":["post-3350","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-solution"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.controlsp.com\/index.php\/wp-json\/wp\/v2\/posts\/3350","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.controlsp.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.controlsp.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.controlsp.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.controlsp.com\/index.php\/wp-json\/wp\/v2\/comments?post=3350"}],"version-history":[{"count":3,"href":"https:\/\/www.controlsp.com\/index.php\/wp-json\/wp\/v2\/posts\/3350\/revisions"}],"predecessor-version":[{"id":3362,"href":"https:\/\/www.controlsp.com\/index.php\/wp-json\/wp\/v2\/posts\/3350\/revisions\/3362"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.controlsp.com\/index.php\/wp-json\/wp\/v2\/media\/2915"}],"wp:attachment":[{"href":"https:\/\/www.controlsp.com\/index.php\/wp-json\/wp\/v2\/media?parent=3350"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.controlsp.com\/index.php\/wp-json\/wp\/v2\/categories?post=3350"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.controlsp.com\/index.php\/wp-json\/wp\/v2\/tags?post=3350"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}